Object 60FFh: Target velocity (DS402)

The speed setpointClosedSetpoint is the target value that an automatic control system, for example PID controller, will aim to reach (target velocity) represents the setpoint for the ramp generator.

Index

60FFh

Name

target velocity, VL.CMDU

Object code

VAR

Data type

INTEGER32

Mode

pv

Access

R/W

PDO mapping

possible

Unit

increments

Value range

(-231) to (231-1)

Default value

Float scaling

1000:1

EEPROM

no


  • "Float Scaling" is applied objects which match floating-point parameters in WorkBench/Telnet. Float scaling "variable" (var) means, that the scaling is not fixed, but depending on other settings or parameters.
    Examples for fixed scaling:
    Object 607Ah is listed as 1:1 - this means that commanding a value of 1000 in SDO 607Ah is equivalent to entering MT.P 1000.000 in WorkBench.
    Object 3598h is listed as 1000:1 - this means that commanding a value of 1000 in SDO 3598h is equivalent to entering ILClosed"Instruction list" This is a low-level language and resembles assembly.KP 1.000 in WorkBench.